NESEA ZERO NET ENERGY BUILDING AWARD Annual Energy Performance Data Applicant Information Name Sara & Gareth Ross Company Address 82 Cottage St E-Mail sara.jane.ross@gmail.com City Amherst Phone (413) 549-5690 State MA Zip Code 1002 Fax Project Summary Project name Ross Residence "Location (city, state)" "Amherst, MA " Building type single-family residence Completion date Jun-10 Owner Sara & Gareth Ross Date occupied Jun-10 Number of days per year the building is fully occupied 360 Typical number of occupants during that period 4 Number of months or years included in the data (12 month minimum required) 13 months Dates of the 'record year' (1-yr period with complete data from which panel will judge bldg.) Nov 2010 - Oct 2011 Conditioned space (in square feet) "3,268" Heating degree days (65oF base) 6405 Unconditioned space (in square feet) "1,200" Cooling degree days (65oF base) 932 Other (in square feet) Degree day data can be found at www.degreedays.net Total building square footage "4,468" (NESEA may confirm and/or adjust to insure uniform reporting of entries.) Project cost (round to nearest dollar) "628,026" Cost per square foot 141 Optional: If there was a perceived incremental cost for greening the building and/ "or integrated design, please quantify in cost/sq. ft. or %. Explain, if appropriate." " Annual Energy Imported, Exported and Site-Produced for All Building Functions" "NET IMPORTED ENERGY (imported/bought = '+', exported/sold = '-')" Units Amount (E)stimated (A)ctual BTU/Unit Total BTU Used Net electricity purchased off site kWh "9,415" A "3,413" "32,133,395" Natural gas Therms 0 A "100,000" 0 Propane Gallons 0 A "91,600" 0 #2 petroleum fuel oil Gallons 0 A "138,200" 0 Cordwood Cord 0 A "20,000,000" 0 Biomass: chips (supply BTU documentation) Ton 0 A 0 Biomass: pellets (supply BTU documentation) Ton 0 A "16,500,000" 0 "Biofuel/fuel oil blend: specify #, ratio, adjust BTUs/gal. if necessary" Gallons 0 A "117,010" 0 Other fuel (specify) 0 A 0 Net Imported Energy Total "32,133,395" Net Imported Energy Intensity* (BTU/sq. ft./year) "7,192" SITE PRODUCED ENERGY Solar electric (used and net export) kWh "15,645" A 3 "46,935" Solar thermal (produced and used onsite) BTU 0 A 1 0 Wind (used and net export) kWh 0 A 3 0 Micro-hydro (used and net export) kWh 0 A 3 0 Site-produced Energy Total "46,935" TotalSite Produced Energy Intensity* (BTU/sq. ft./year) 11 * Total net from 1 year of utility bills; 1 year audit report from utility must include complete time period. Audit should " be sent directly to NESEA from your utility (mail, fax or email). Note: '-'= utility credit and '+' = utility charges" Annual Energy by End-Use (optional - complete if possible) Heating (enter appropriate BTU amount from above) BTU E or A? 1 0% Cooling kWh E or A? 3.41 0% Fans and pumps kWh E or A? 3.41 0% Domestic hot water (enter appropriate BTU amount from above) BTU E or A? 1 0% Plug loads and equipment kWh E or A? 3.41 0% Other end use (specify and enter appropriate BTUs from above) E or A? 0%