Indra's Energy+ Household

Project Subtitle: 

Net positive energy with day to day transportation for 5 years running

Project Description: 

This projects describes the steps taken to retrofit an exsiting single family home in Cupertino California to be net energy positive including daily transportation needs. The house has maintained net energy positive status for 5 years straight showing the sustainability of the approach. No major sacrifices were made in the comfort and convinienece of the household members in the process. 

Building Type Summary: 

Single-family residence

Address: 

18870 Barnhart Avenue
Cupertino, CA 95014
United States

Elevation: 

240

Lat. / Long.: 

POINT (-122.001994 37.315261)

Location Type: 

Suburaban

Köppen Climate Type: 

Csb

Climate Region: 

Zone 4

Solar Insolation: 

5.35 kWh/m2/day

Annual HDD : 

2649

Annual CDD: 

30

HDD Base Temp: 

65

CDD Base Temp: 

80

Occupancy Type and Details: 

Owner occupied. 4 full time occupants. 2 adults and 2 children. Both adults working. Children go to school. 5 weeks per year average unoccupied due to vacations. Occasional guests.

Number of stories: 

1

Conditioned Floor Area: 

2 170

Conditioned Building Volume: 

20 000

Unconditioned Floor Area: 

500

Multiple buildings?: 

Total number of units in project (all buildings): 

1

Total floor area of project (all buildings): 

2 670

Historic?: 

Completion date: 

Tuesday, December 20, 2011

Site description: 

Normal suburban plot about 6000 sq ft. Street has houses on both sides. Backs to another similar house on a similar street at the back.

Materials: 

House built to California Code in 1997. Nothing special. Stucco on frame. Concrete slab. Insulation is wall and attic according to code. Double pane windows. Wooden doors. Has large south facing roof suitable for solar panels. Also not of South facing windows to let in winter sun.

Energy Highlights: 

All electric home. Natural gas completely disconnected for 5 years now. 2 EV charging stations - 1 level 2, 1 level 1

Annual renewable energy generated: 

15 500

Power Rating: 

11 800Watts

Electric Utility Company: 

PG&E

Gas Utility Company: 

NA

Datasets and Utility Bills sources and reliability: 

Completely reliable as the bills and usage data used are actual ones from PG&E.

Electricity amount (imported from grid): 

11 000

Electricity amount (credited or exported to grid): 

12 500

Net electricity usage (purchased electricity): 

-1 500

Natural gas amount (purchased energy): 

0

Energy Strategies: 

Increase efficiency thorough reasonable retrofits. Electrify everything by eliminating natural gas appliances. Convert automobiles to EVs. Monitor energy usage for a year. Install net-metered solar system sized to cancel out all the used electricity over the year.

Energy Use and Production Documentation: 

Number of Bathrooms: 

3.00

Site conditions: 

previously developed land

Renewable Energy Sources: 

Renewable energy is generated within the building footprint (e.g. solar PV on the roof)

Number of Bedrooms: 

4

Status: 

Live

Zero Net Energy Definition Used: 

Site Energy Use

Basis of Performance Claim: 

Verified

Type of Construction: 

Retrofit

Renewable Energy System Type(s): 

Photovoltaics

Renewable Energy System Description & Details: 

40, 295 W Canadian solar mono-crystalline modules (CS6X-295M) meted with a Fronius 11.4 KW single phase inverter. The array faces 40% east, 40% west and 20% south. Half of the array is equipped with Tigo optimizers to optimize output.

Annual Renewable Energy Generated Data Type: 

Measured

Source of Annual Production Data: 

Metered through remote monitoring and also displayed at the inverter panel.

Days per year Building is fully occupied: 

330

Submitter Contact Email: 

Submitter Contact Phone Number: 

(408) 530-4559

Project Type: 

Net Exporter

Weight: 