Walls and Roof

Typical single-family residential construction, with 2x4 16oc framing, slab-on-grade foundation, and concrete roof tile. We used high-density R-15 batt insulation in the walls along with a continuous layer of R-4 rigid insulation board on the exterior.

Subslab assembly

Standard slab-on-grade concrete foundation.

Subslab R-value 0.0
Slab edge assembly

Used no slab insulation as we are in a hot climate.

Slab edge R-value 0.0
Above grade wall R-value 19.0
Flat attic assembly

Truss framed attic with furnace/air handler mounted within. 30% of duct work remained in attic, but was buried in loose-fill fiberglass blow. The remainder was run below the thermal boundary.

Flat attic R-value 60.0
Roof Assembly

Typical concrete roof tile assembly. Cool Roof concrete tile product was installed.

Windows and Doors

Window Assembly:

Monte Verde Windows: Vinyl, dual-pane, triple-layer low-E, argon gas-filled windows made by Anlin in Clovis, CA.

Average window U-factor 0.26
Solar Heat Gain Coefficient 0.21
Visible Light Transmittance 0.64

Mechanical Systems

Space cooling - Manufacturer & Model Lennox
Space heating - Manufacturer & Model Lennox
Domestic hot water - Manufacturer & Model Rheem Heat Pump Water Heater
Ventilation - Manufacturer & Model Integrated system utilizing ECM with forced-air HVAC
Lighting Manufacturer and Model 100% LED throughout. Variety of manufacturers.
Lighting Efficiency

Envelope

Air Changes per hour, ACH50 3.00 ACH50
Air Changes per hour, CFM50