"The Groton" Model
23 Coppersmith Way, Townsend, MA
Walls and Roof
Subslab assembly
2" rigid, R-10
Subslab R-value
10.0
Slab edge assembly
2" rigid, R-10
Slab edge R-value
10.0
Foundation wall assembly
3.5" closed cell foam, R-20
Foundation wall R-value
20.0
Above grade wall assembly
12" open cell foam, R-46.8 cavity
Above grade wall R-value
46.8
Flat attic assembly
18" cellulose, R-67
Flat attic R-value
67.0
Windows and Doors
Window Assembly:
Windows U-value of 0.20, SHGC of 0.26
Average window U-factor
0.20
Solar Heat Gain Coefficient
0.26
Mechanical Systems
Space cooling - Manufacturer & Model
2 Mitsubishi mini splits, MSZ-FE12NA indoor units, MUZ-FE12NA outdoor units
Space heating - Manufacturer & Model
2 Mitsubishi mini splits, MSZ-FE12NA indoor units, MUZ-FE12NA outdoor units
Domestic hot water - Manufacturer & Model
Navien 180, 98% efficient
Ventilation - Manufacturer & Model
Fantech 1504 HRV
Lighting Manufacturer and Model
Compact florescent
Lighting Efficiency
23 Coppersmith Way, Townsend, MA
Walls and Roof
Subslab assembly |
2" rigid, R-10 |
---|---|
Subslab R-value | 10.0 |
Slab edge assembly |
2" rigid, R-10 |
Slab edge R-value | 10.0 |
Foundation wall assembly |
3.5" closed cell foam, R-20 |
Foundation wall R-value | 20.0 |
Above grade wall assembly |
12" open cell foam, R-46.8 cavity |
Above grade wall R-value | 46.8 |
Flat attic assembly |
18" cellulose, R-67 |
Flat attic R-value | 67.0 |
Windows and Doors
Window Assembly:
Windows U-value of 0.20, SHGC of 0.26
Average window U-factor | 0.20 |
---|---|
Solar Heat Gain Coefficient | 0.26 |
Mechanical Systems
Space cooling - Manufacturer & Model | 2 Mitsubishi mini splits, MSZ-FE12NA indoor units, MUZ-FE12NA outdoor units |
---|---|
Space heating - Manufacturer & Model | 2 Mitsubishi mini splits, MSZ-FE12NA indoor units, MUZ-FE12NA outdoor units |
Domestic hot water - Manufacturer & Model | Navien 180, 98% efficient |
Ventilation - Manufacturer & Model | Fantech 1504 HRV |
Lighting Manufacturer and Model | Compact florescent |
Lighting Efficiency |