Walls and Roof

Increased R-values of basement floors to 20, basement walls to 40, exterior walls to 40, cathedral ceilings to 60, and flat ceilings to 70

Subslab assembly

n/a

Subslab R-value 20.0
Slab edge assembly

Since this was a retrofit, could not insulate slab edge. I stead slab was insulated on top with 2 inches of ridged foam and sheathed with 3/4" t&g plywood

Foundation wall assembly

4 inches of polyiso, and 4 inches of fiberglass batts on inside of foundation wall. All joints in polyiso were sealed.

Foundation wall R-value 40.0
Above grade wall assembly

Existing 2x4 walls with 1/2

Above grade wall R-value 40.0
Flat attic assembly

1/2" drywall, 5" blown-in cellulose (existing), 2" polyiso sheathing, 12" blown-in cellulose, perimeter spray foamed for air sealing

Flat attic R-value 70.0
Cathedral ceiling assembly

1/2" drywall, Smart-poly membrane, 5-1/2" dense pack cellulose, 5-1/2" closed cell foam

Cathedral ceiling R-value 60.0
Roof Assembly

n/a

Windows and Doors

Window Assembly:

South facing: Weather Shield, triple pane with Cardinal 180, clear,180: SHGC = 0.56
All others, Marvin Integrity, triple pane with Cardinal 282, clear, 282: SHGC = 0.32

Door Assembly:

Therma-Tru solid core

Average window U-factor 0.17
Solar Heat Gain Coefficient 0.56
Visible Light Transmittance 0.41
Door U-Factor 0.10
Door Area 21 sq ft

Mechanical Systems

Space heating - Manufacturer & Model Fitjitsu Min-split Heat Pump
Space heating - capacity 24 kW
Domestic hot water - Manufacturer & Model GE GEH80DEEJSC Heat Pump Water Heater
Domestic hot water - capacity 80 gal
Domestic hot water - efficiency 320 kW
Ventilation - Manufacturer & Model Zehnder HRV
Lighting Manufacturer and Model All LED
Lighting Efficiency 100
Mechanical Equipment Installation Details and Comments

A blower door test will be performed when house gets near completion. All penetrations were sealed from inside and outside. Condensing dryer and re-circulating range hood preclude big holes in envelope