Walls and Roof

This project was designed to meet the PHIUS+ standards, with a robust thermal envelope and simple shape for affordability and constructability.

Subslab assembly

Exposed concrete slab with 6" EPS.

Subslab R-value 25.2
Slab edge R-value 16.8
Above grade wall assembly

Double Stud wall. 2x6 outer, 3" gap, 2x4 inner. 4" closed cell foam Lapolla Foam Lok 2000-4g, 8" blown in fiberglass.

Above grade wall R-value 56.0
Roof Assembly

Truss filled with 24" blown in cellulose.

Roof R-value 91.7

Windows and Doors

Window Assembly:

Schuco PVCU, Triple glazed

Door Assembly:

Schuco

Average window U-factor 0.13
Solar Heat Gain Coefficient 0.50

Mechanical Systems

Space cooling - Manufacturer & Model Daiken Quaternity FTXG12HVJU indoor & RXG12HVJU outdoor
Space heating - Manufacturer & Model Daiken Quaternity FTXG12HVJU indoor & RXG12HVJU outdoor
Domestic hot water - Manufacturer & Model GE Geospring Heat Pump Hot Water Heater
Domestic hot water - capacity 80 gal
Ventilation - Manufacturer & Model Zehnder ERV ComfoAir 350
Lighting Manufacturer and Model
Lighting Efficiency

Envelope

Air Changes per hour, ACH50 0.02 ACH50
Air Changes per hour, CFM50