Walls and Roof

Building envelope was designed to the Passive House Standard

Subslab assembly

4" XPS 4" gravel 10 mil. vapor retarder

Subslab R-value 21.3
Slab edge assembly

4" XPS

Slab edge R-value 21.3
Foundation wall assembly

From exterior to interior - 1.5" XPS 8" concrete 2" XPS 7.5" blown in cellulose 2 x 4 wood stud with 5/8 drywall

Foundation wall R-value 46.3
Above grade wall assembly

From exterior to interior - 1" XPS 1/2" OSB 2.5" Spray Foam 2 x 6 staggered stud @ 24" O.C. 8.5" cellulose 2 x 4 staggered stud at 24" O.C. 5/8" drywall

Above grade wall R-value 47.5
Roof Assembly

wood roof trusses at 24" o.c.

Roof R-value 54.6

Windows and Doors

Window Assembly:

Alpen 925 Series Fiberglass Low E

Door Assembly:

Therma Tru Insulated Frame

Average window U-factor 0.12
Solar Heat Gain Coefficient 0.28
Door U-Factor 0.90
Door Area 20 sq ft

Mechanical Systems

Space cooling - Manufacturer & Model Fist Co Evaporator Coil
Space heating - Manufacturer & Model First Co. Hydronic Fan Coil
Domestic hot water - Manufacturer & Model Navien Condensing Combi Gas Boiler
Ventilation - Manufacturer & Model Zehnder Comfo Air 350 ERV
Lighting Manufacturer and Model
Lighting Efficiency

Envelope

Air Changes per hour, ACH50 0.60 ACH50
Air Changes per hour, CFM50