Walls and Roof

Subslab assembly

4” EPS under whole slab

Subslab R-value 20.0
Slab edge assembly

3” EPS at slab joint

Slab edge R-value 15.0
Foundation wall assembly

2” EPS panel to 48” depth

Foundation wall R-value 10.0
Above grade wall assembly

gym wall: 17” of cellulose insulation, all other spaces: 8” of cellulose and 2” of Poly-isocyanurate

Above grade wall R-value 45.0
Flat attic assembly

9” continuous Poly-isocyanurate

Flat attic R-value 60.0

Windows and Doors

Window Assembly:

a. Triple-glazed, low-e, argon filled: U-value – 0.15, SHGC – 0.28, VT – 0.49
b. Skylights in wellness spaces and offices (Velux), double-glazed, low-e, argon filled: U-value – 0.4, SHGC – 0.34, VT – 0.54
c. Skylights in gymnasium (Sun Optics), triple-glazed, prismatic acrylic: U-value – 0.35, SHGC – 0.74, VT – 0.66

Average window U-factor 0.15
Solar Heat Gain Coefficient 0.28
Visible Light Transmittance 0.49

Mechanical Systems

Space cooling - Manufacturer & Model Daikin Multi-City VRV air source heat pumps
Space heating - Manufacturer & Model Daikin Multi-City VRV air source heat pumps
Domestic hot water - Manufacturer & Model Lavatory water heater, 0.75 GPM instantaneous, 100°F, EX65TFS-100°, Heat pump water heater, E-Tech R060 80 gal electric water heater
Lighting Manufacturer and Model
Lighting Efficiency