Transformations---15 Laurel Street, Northampton, MA
Walls and Roof
Super-insulation of the building with 12" think walls.
Subslab assembly
2" of rigid under the basement slab.
Subslab R-value
10.0
Slab edge assembly
2" of rigid.
Slab edge R-value
10.0
Foundation wall assembly
3.5" of high density foam.
Foundation wall R-value
22.2
Above grade wall assembly
12" of double studded wall mostly filled with medium density foam.
Above grade wall R-value
49.0
Flat attic assembly
18" of blown cellulose.
Windows and Doors
Average window U-factor
0.21
Solar Heat Gain Coefficient
0.20
Mechanical Systems
Space cooling - Manufacturer & Model
Mitsubishi MSZ-FE12NA & FE9NA heads and MUZ-FE12NA & FE9NA condensers
Space heating - Manufacturer & Model
Mitsubishi MSZ-FE12NA & FE9NA heads and MUZ-FE12NA & FE9NA condensers
Domestic hot water - Manufacturer & Model
AO Smith heat pump hot water heater
Domestic hot water - capacity
50 gal
Ventilation - Manufacturer & Model
Panasonic Whisper Green bathroom ventilation fan, 30-70 CFM
Lighting Manufacturer and Model
Lighting Efficiency
Envelope
Air Changes per hour, ACH50
1.00 ACH50
Air Changes per hour, CFM50
385.00
Walls and Roof
Super-insulation of the building with 12" think walls.
Subslab assembly |
2" of rigid under the basement slab. |
---|---|
Subslab R-value | 10.0 |
Slab edge assembly |
2" of rigid. |
Slab edge R-value | 10.0 |
Foundation wall assembly |
3.5" of high density foam. |
Foundation wall R-value | 22.2 |
Above grade wall assembly |
12" of double studded wall mostly filled with medium density foam. |
Above grade wall R-value | 49.0 |
Flat attic assembly |
18" of blown cellulose. |
Windows and Doors
Average window U-factor | 0.21 |
---|---|
Solar Heat Gain Coefficient | 0.20 |
Mechanical Systems
Space cooling - Manufacturer & Model | Mitsubishi MSZ-FE12NA & FE9NA heads and MUZ-FE12NA & FE9NA condensers |
---|---|
Space heating - Manufacturer & Model | Mitsubishi MSZ-FE12NA & FE9NA heads and MUZ-FE12NA & FE9NA condensers |
Domestic hot water - Manufacturer & Model | AO Smith heat pump hot water heater |
Domestic hot water - capacity | 50 gal |
Ventilation - Manufacturer & Model | Panasonic Whisper Green bathroom ventilation fan, 30-70 CFM |
Lighting Manufacturer and Model | |
Lighting Efficiency |
Envelope
Air Changes per hour, ACH50 | 1.00 ACH50 |
---|---|
Air Changes per hour, CFM50 | 385.00 |