Walls and Roof
2x6 timber stud walls on 16 centers, 7/16 OSB sheathing and Tyvex wrapped. Tight insulation as described below
Above grade wall assembly |
2x6 timber stud walls on 16 centers, 7/16 OSB sheathing and Tyvek wrapped. R-21 dense pack cellulose insulation full cavity, Joist ends and bands foamed. |
---|---|
Above grade wall R-value | 21.0 |
Flat attic assembly |
blown in cellulose insulation in flat attic surfaces |
Flat attic R-value | 49.0 |
Cathedral ceiling assembly |
Fiberglass batt insulation in cathedral ceiling spaces |
Cathedral ceiling R-value | 38.0 |
Roof Assembly |
30 # felt under asphalt architectural shingles. Continuous Soffit vents at eaves with ridge vent on shingles, Blown in cellulose on flat ceiling surfaces as noted above |
Windows and Doors
Window Assembly:
Jeld-Wen Energy Star Rated windows
Average window U-factor | 0.23 |
---|---|
Solar Heat Gain Coefficient | 0.28 |
Visible Light Transmittance | 0.52 |
Mechanical Systems
Space cooling - Manufacturer & Model | Water Furance Series 5 NDH049 |
---|---|
Space cooling - capacity | 15 kW |
Space heating - Manufacturer & Model | Water Furance Series 5 |
Space heating - capacity | 11 kW |
Lighting Manufacturer and Model | LED Lighting throughout |
Lighting Efficiency |