General Energy Use, Strategies and Systems

Energy Use:

Passive House PHIUS+ certified. House designed to face true South. 8.7 kw PV system, sized for house load plus future EV. Pre wired for garage EV electric car charger. Motorized exterior solar shade.

Energy Strategies:

All electric house. No combustion in Passive House envelope.

Zero Net Energy Definition Used Site Energy Use

Monthly Energy Data and Utilities

Energy Data Type:
Zero Energy Program
Electric Utility:
Eversource
Gas Utility:
National Grid
Other purchased Fuels:

no

Datasets and utility bills:
AttachmentSize
PDF icon doechallenge_with_pv.pdf2.03 MB
Datasets and utility bills sources and reliability:

source is utility bills and pv meter readings (for SREC program)

Cogeneration

Cogeneration System Description:

NA

Renewables and Energy Balance

Renewable Energy Sources:
Renewable energy is generated within the building footprint (e.g. solar PV on the roof)
Renewable Energy System Description & Details
33 Suniva Optimus black modules (USA manufactured Compliant) at 265 watt DC each. Enphase M250 micro inverters.
Annual renewable energy generated 11,434 kWh
Annual Renewable Energy Generated Data Type Measured
Power Rating Renewable Energy System Type(s) Source of Annual Production Data
8,745Watts Photovoltaics, Geothermal 11,434 kwh measured year 1 gross annual production (compared to PV Watt predicted of 10,991 or 4% better)

Storage and Installed Capacity

NA

Energy Storage type

house naturally stores heat energy in winter due to Passive House construction. No other storage devices are used.

Energy Storage Capacity

Annual Energy Import/Export

Electricity amount (credited or exported to grid) 11,434 kWh/year