Cape Cod Passive House
Walls and Roof
Walls are double stud construction, 14 inch total insulated thickness
Subslab assembly |
10 inches of EPS, 6 mil poly sheet, 4 inch concrete, 1.5 inch EPS between sleeper studs. Total of 11.5 inches EPS. R values are for entire assembly from PHPP Model. |
---|---|
Subslab R-value | 48.3 |
Slab edge assembly |
perimeter thermally isolated from stem wall with 4 inch EPS |
Slab edge R-value | 16.5 |
Foundation wall assembly |
10 inch thick concrete stem wall |
Foundation wall R-value | 0.3 |
Above grade wall assembly |
2x6 16" o.c. outer wall, 4 inch space, 2x4 inner stud wall for a total insulated thickness of 14 inches. 4 inch closed cell foam on sheathing, and 10 inches dense pack dry cellulose. R values are for entire assembly from PHPP Model. |
Above grade wall R-value | 52.2 |
Flat attic assembly |
24 inches blown in cellulose between trusses. R values from PHPP Model. |
Flat attic R-value | 91.7 |
Cathedral ceiling assembly |
NA |
Windows and Doors
Window Assembly:
triple pane wood tilt turn windows with aluminum clad by Makrowin (Yaro). R values are for entire assembly from PHPP Model.
Door Assembly:
triple pane argon glass with wood frame aluminum clad, same construction as windows. R values are for entire assembly from PHPP Model.
Average window U-factor | 0.15 |
---|---|
Solar Heat Gain Coefficient | 0.62 |
Visible Light Transmittance | 0.73 |
Door U-Factor | 0.15 |
Door Area | 29 sq ft |
Mechanical Systems
Space cooling - Manufacturer & Model | Daiken Quaternity heat pump 12000 btu FTXG12HVJU & RXG12HVJU |
---|---|
Space cooling - capacity | 4 kW |
Space heating - Manufacturer & Model | Daiken Quaternity heat pump 12000 btu FTXG12HVJU & RXG12HVJU |
Space heating - capacity | 5 kW |
Domestic hot water - Manufacturer & Model | AO Smith heat pump PHPT-80 (EF=2.33) |
Domestic hot water - capacity | 80 gal |
Domestic hot water - efficiency | 2 kW |
Ventilation - Manufacturer & Model | Zehnder Comfo Air 350 and Comfo Fond-L |
Lighting Manufacturer and Model | LED various manufacturers |
Lighting Efficiency | |
Mechanical Equipment Installation Details and Comments |
Each ventilation port was measured and set by a certified Zehnder commissioning expert |
Envelope
Air Changes per hour, ACH50 | 0.37 ACH50 |
---|---|
Air Changes per hour, CFM50 |