Walls and Roof

Walls are double stud construction, 14 inch total insulated thickness

Subslab assembly

10 inches of EPS, 6 mil poly sheet, 4 inch concrete, 1.5 inch EPS between sleeper studs. Total of 11.5 inches EPS. R values are for entire assembly from PHPP Model.

Subslab R-value 48.3
Slab edge assembly

perimeter thermally isolated from stem wall with 4 inch EPS

Slab edge R-value 16.5
Foundation wall assembly

10 inch thick concrete stem wall

Foundation wall R-value 0.3
Above grade wall assembly

2x6 16" o.c. outer wall, 4 inch space, 2x4 inner stud wall for a total insulated thickness of 14 inches. 4 inch closed cell foam on sheathing, and 10 inches dense pack dry cellulose. R values are for entire assembly from PHPP Model.

Above grade wall R-value 52.2
Flat attic assembly

24 inches blown in cellulose between trusses. R values from PHPP Model.

Flat attic R-value 91.7
Cathedral ceiling assembly

NA

Windows and Doors

Window Assembly:

triple pane wood tilt turn windows with aluminum clad by Makrowin (Yaro). R values are for entire assembly from PHPP Model.

Door Assembly:

triple pane argon glass with wood frame aluminum clad, same construction as windows. R values are for entire assembly from PHPP Model.

Average window U-factor 0.15
Solar Heat Gain Coefficient 0.62
Visible Light Transmittance 0.73
Door U-Factor 0.15
Door Area 29 sq ft

Mechanical Systems

Space cooling - Manufacturer & Model Daiken Quaternity heat pump 12000 btu FTXG12HVJU & RXG12HVJU
Space cooling - capacity 4 kW
Space heating - Manufacturer & Model Daiken Quaternity heat pump 12000 btu FTXG12HVJU & RXG12HVJU
Space heating - capacity 5 kW
Domestic hot water - Manufacturer & Model AO Smith heat pump PHPT-80 (EF=2.33)
Domestic hot water - capacity 80 gal
Domestic hot water - efficiency 2 kW
Ventilation - Manufacturer & Model Zehnder Comfo Air 350 and Comfo Fond-L
Lighting Manufacturer and Model LED various manufacturers
Lighting Efficiency
Mechanical Equipment Installation Details and Comments

Each ventilation port was measured and set by a certified Zehnder commissioning expert

Envelope

Air Changes per hour, ACH50 0.37 ACH50
Air Changes per hour, CFM50