Walls and Roof

Rebuilt the entire shell and thermal boundary to increase insulation values and tighten the air barrier.

Subslab assembly

6" EPS foam

Subslab R-value 24.0
Slab edge assembly

3" EPS foam

Slab edge R-value 12.0
Foundation wall assembly

The home was lifted off of its old foundation and excavated to increase its footprint. A new foundation and slab were poured with 3” exterior EPS foam to the outside of the foundation walls, and 6” of EPS insulation under the slab and footings. The home was placed back down and the original first and second story floor systems were preserved.

Foundation wall R-value 12.0
Above grade wall assembly

All existing 2x4 walls were furred out to 5.5” and new walls were all 2x6 construction. These were sheathed with Zip System sheathing, and the joints and seams were sealed with the Prosoco liquid flash system. To the exterior of the sheathing, Birdsmouth added 2” of cork insulation followed by a fully vented rainscreen assembly and cedar lap siding. The interior wall cavities were filled with 5.5” of dense pack cellulose.

Above grade wall R-value 28.0
Cathedral ceiling assembly

The roof assembly was built from 2x12 rafters, which the wall sheathing went up and over. This allowed for dense pack cellulose in the vaulted ceilings. Over the sheathing, which acted as the primary vapor control layer and the air barrier, 2x6 rafters were installed to create a space for 3.5” of rockwool insulation and a vent space. The tails ran long over the wall plane to create the overhangs for the building. This was then sheathed and a metal roof was installed. Soffit vents and a ridge vent provided for ventilation of these cavities.

Cathedral ceiling R-value 44.0

Windows and Doors

Window Assembly:

Triple pane, wood/clad Zola windows and doors were used, including 3 large lift slide units. The average U value of the windows is U.12. The windows were installed into the rough openings with Hanno Band expanding foam tape.

Door Assembly:

wood/clad Zola doors

Average window U-factor 0.12
Door U-Factor 0.14
Door Area 38 sq ft

Mechanical Systems

Space cooling - Manufacturer & Model DHP
Space heating - Manufacturer & Model DHP
Domestic hot water - Manufacturer & Model Electric
Domestic hot water - capacity 66 gal
Ventilation - Manufacturer & Model Zehnder Comfo Air HRV
Lighting Manufacturer and Model
Lighting Efficiency 100%
Mechanical Equipment Installation Details and Comments

Blower door test performed on home. HRV balanced and commissioned.

Envelope

Air Changes per hour, ACH50 0.54 ACH50
Air Changes per hour, CFM50