Walls and Roof

Subslab assembly

Rigid insulation installed under slab on grade

Subslab R-value 36.0
Slab edge assembly

Rigid insulation installed at slab on grade edge

Slab edge R-value 19.5
Above grade wall assembly

The Double 2x4 stud wall with 5” gap has a 12” depth. Insulation includes R-22 (3.5” at R-6.3/in) closed cell spray foam and R-30 cellulose (8.5” at R-3.5/in) were installed in this double stud wall. Walls are sheathed by ZIPS with taped seams. The exterior finish is a rain screen with cementitious siding.

Above grade wall R-value 52.0
Flat attic assembly

25" of cellulose (R-3.6/in) is sprayed in the attic.

Flat attic R-value 90.0

Windows and Doors

Window Assembly:

Triple-pane, Low-e windows

Average window U-factor 0.17
Solar Heat Gain Coefficient 0.62

Mechanical Systems

Space cooling - Manufacturer & Model none installed
Space heating - Manufacturer & Model Electric baseboard
Domestic hot water - Manufacturer & Model Solar thermal (Thermo Ray) preheat with electric storage tank, 0.94 EF
Domestic hot water - capacity 80 gal
Domestic hot water - efficiency 94 kW
Ventilation - Manufacturer & Model ERV, UltimateAir RecoupAerator
Lighting Manufacturer and Model
Lighting Efficiency

Envelope

Air Changes per hour, ACH50 0.42 ACH50
Air Changes per hour, CFM50