Walls and Roof

Subslab assembly

Subslab 4” extruded polystyrene

Subslab R-value 20.0
Slab edge assembly

Slab edge 2” of foam

Foundation wall assembly

House is on a slab, no basement

Above grade wall assembly

Above-grade wall 2x4 double wall (9.25”cavity) dense pack cellulose

Above grade wall R-value 34.0
Flat attic assembly

Flat attic 2x10 and 2x8 (16.5” cavity) dense pack cellulose

Flat attic R-value 63.0
Cathedral ceiling assembly

Cathedral ceiling (including sloped attic ceiling) 2x12 with horizontal strapping (12.75” cavity) dense pack cellulose

Cathedral ceiling R-value 43.0

Windows and Doors

Window Assembly:

North-facing: Marvin Windows, 1 clad casement and 2 awning tripane u=.25 SHGC =.25
West-facing: 1 Marvin clad casement double pane u=.35 SHGC =.47
East-facing: 2 Marvin clad double-hung u=.30 SHGC =.30
South-facing: 4 Marvin clad double-hung u=.30 SHGC=.30
10 Marvin clad casement double pane u=.35 SHGC=.47
3 Velux VS skylights u=.50 SHGC=.29
*Only windows on walls within the conditioned space are listed. Over 75% of the surface of these windows faces south.

Door Assembly:

Doors: 4 (including attic door) ThermaTru R-7 u=.14

Average window U-factor 0.34
Solar Heat Gain Coefficient 0.37
Door U-Factor 0.14

Mechanical Systems

Space cooling - Manufacturer & Model Space Cooling Not Needed
Space heating - Manufacturer & Model GeoStar EWO 30H10SSA 3-ton open loop geothermal heat pump to drilled well
Domestic hot water - Manufacturer & Model 2 Heliodyne roof mounted Golbi 408 solar hot water panels
Ventilation - Manufacturer & Model Venmar Constructo 41500 1.p air to air heat recovery unit for ventilation
Lighting Manufacturer and Model
Lighting Efficiency 21 hard-wired florescent fixtures, all other lamps and fixtures have compact florescent bulbs
Mechanical Equipment Installation Details and Comments

Superstor Contender Solar tank (SE series, electric back-up), GFX heat-recovery coil for 2nd floor bath