Kane Family Residence
Walls and Roof
Subslab assembly |
2” XPS Foamular R10 |
---|---|
Subslab R-value | 10.0 |
Foundation wall assembly |
3.5” closed cell polyurethane foam, 2.5” polyisocyanurate R36 |
Foundation wall R-value | 36.0 |
Above grade wall assembly |
Double 2x4 wall construction – very little thermal bridging |
Above grade wall R-value | 42.0 |
Roof Assembly |
External roof insulation: 4.5” polyisocyanurate Hunter Panels Cool – Vent R18.5, 1” air gap |
Roof R-value | 63.0 |
Windows and Doors
Window Assembly:
Thermotech casement style, fiberglass, triple pane, argon filled, U value 0.19
Different glass with higher SHGC of .64 used on south side for more passive solar gain
No sloped glass
Double cell honeycomb shades
Door Assembly:
Steel, insulated U.16
Average window U-factor | 0.19 |
---|---|
Solar Heat Gain Coefficient | 0.64 |
Door U-Factor | 0.16 |
Mechanical Systems
Space heating - Manufacturer & Model | Roth ¾” radiant floor panels. One zone, six loops of 3/8 PEX tubing – in first floor only, TEKMAR tN2 House Control 400 outdoor reset, networked thermostats, Caleffi manifold, Taco 009 circulator pump, 1500 W electric fireplaces in each bedroom, rarely used |
---|---|
Domestic hot water - Manufacturer & Model | Four (4’ x10’) Heliodyne Gobi flat plate collectors – 160 sq.ft. |
Domestic hot water - capacity | 488 gal |
Ventilation - Manufacturer & Model | Two Fantech SHR 1505 142 CFM air to air heat exchangers, Venmar Transition Tandem exterior vent |
Lighting Manufacturer and Model | 2700K LEDS and compact fluorescents used exclusively |
Lighting Efficiency | No lights are needed during the day |
Mechanical Equipment Installation Details and Comments |
Solar hot water system: Radiant floor heat system (first floor only): Msc: |
Envelope
Air Changes per hour, ACH50 | 0.60 ACH50 |
---|---|
Air Changes per hour, CFM50 |