Poplar House
General Energy Use, Strategies and Systems
Energy Use:
18.55 kW PV. DWHR unit for water. Automation systems will be used when possible. Other than generator and outside grill, no fossil fuel will be used to heat, cool, cook, or heat water on site. Ground loop for HRV.
Energy Strategies:
All electric, no fossil fuel, LED, Heat pump dryer, heat pump water heater, DWHR, recirculating hot water, ground loop HRV, mini-split heat pump, back up radiant electric, triple pane windows, high efficient HRV/ERV, occupancy sensors, Induction stove, super insulation.
Zero Net Energy definition is not defined as of yet.
Zero Net Energy Definition Used | Site Energy Use |
---|
Monthly Energy Data and Utilities
No
Attachment | Size |
---|---|
![]() | 181.18 KB |
![]() | 75.78 KB |
![]() | 1.04 MB |
![]() | 132.04 KB |
Poplar House
Renewables and Energy Balance
Renewable Energy System Description & Details |
---|
Solar Edge 10kw inverter. Solar Edge 6kW inverter. 18.55 kW system. Comprised of 70 SolarWorld 265w panels. Two arrays. 10kW inverter comprised of 48 panels, using three strings of 16 panels on the garage. 6kW inverter comprised of 22 panels, using two strings of 11 panels on the house. |
Annual renewable energy generated | 18,550 kWh |
---|---|
Annual Renewable Energy Generated Data Type | Modeled |
Power Rating | Renewable Energy System Type(s) | Source of Annual Production Data |
---|---|---|
18,550Watts | Photovoltaics | PVWatts - estimated gross annual production |