Sandywoods Farm Net Zero Spec House #1
Lot 8 Sandywoods Farm Net Zero
General Energy Use, Strategies and Systems
Energy Strategies:
Conservation 1st, energy generation 2nd. Super insulate, ensure envelope tightness below 1 ACH/50, super high efficiency HVAC and hot water heating, then generate adequate electricity with south facing solar array to heat, cool, heat water, and provide all typical plug loads.
Zero Net Energy Definition Used | Site Energy Use |
---|
Monthly Energy Data and Utilities
Energy Data Type:
Modeled
Electric Utility:
National Grid
Gas Utility:
N/A
Other purchased Fuels:
N/A
Datasets and utility bills:
Datasets and utility bills sources and reliability:
Mark Rosenbaum's Net Zero Homes Modeling Software
Sandywoods Farm Net Zero Spec House #1
Renewable Energy System Description & Details |
---|
33 Solpower 275kW photovoltaic panels connected to 33 Enphase microinverters. |
Annual renewable energy generated | 10,890 kWh |
---|---|
Annual Renewable Energy Generated Data Type | Modeled |
Power Rating | Renewable Energy System Type(s) | Source of Annual Production Data |
---|---|---|
9,075Watts | Photovoltaics | Estimated gross annual production |
Storage and Installed Capacity
N/A
Energy Storage type |
Grid tied system w/revenue grade meter |
---|---|
Energy Storage Capacity |
Annual Energy Import/Export
Electricity amount (imported from grid) | 10,890 kWh/year |
---|---|
Electricity amount (credited or exported to grid) | 10,890 kWh/year |